The NCSC Cyber Assessment Framework provides a useful basis for assessing cyber resilience. Outcomes-based, it defines what an organisation needs to achieve without prescribing a single way of achieving it.
It also creates a challenge. The CAF is sector-agnostic, meaning an assessment cannot stop at determining whether an outcome appears to have been achieved, but must examine the management functions that deliver and sustain that outcome in the organisation’s particular context.
For operational technology, they must also reflect what the systems protect: physical processes, hazardous inventories, critical equipment, and, in some cases, safety instrumented functions. The harder question is therefore not whether this outcome is achieved, but whether the underlying arrangements provide sufficient evidence that the outcome is being—and will continue to be—achieved.
Outcomes depend on interconnected functions
Answering that requires more than a checklist, because management functions do not operate independently. Process safety offers a useful analogy. Effective emergency response depends on competent people and reliable assets. Changes to any of them must be controlled through a management of change process that itself considers the consequences for emergency response.
OT cyber resilience has the same shape. A control system asset may support an alarm, interlock, safety instrumented function or emergency shutdown. Its resilience can depend on system architecture, access control, supplier arrangements, vulnerability management, monitoring, competence, incident response and recovery. A weakness in one function may affect several others.
An outcome can therefore appear to have been achieved in isolation, even though the arrangements supporting it are incomplete, poorly connected, or no longer effective.
Detail is not the same as unnecessary complexity
Structured assessment is sometimes mistaken for excessive detail. The purpose is not to document everything indiscriminately, but to examine the arrangements systematically enough to identify the gaps, inconsistencies and dependencies that a high-level review can miss.
A policy may exist but not be reflected in site procedures. Remote access may be controlled, but exceptions may have developed around supplier support. Each control may appear reasonable on its own, while the cracks lie in the connections between them. Those cracks matter because an adversary does not need every control to fail; they need one viable route, often created by a sequence of individually modest weaknesses.
What the evidence shows
HSE’s OT cyber trial inspection programme illustrates the difference between assumed and evidence-based assurance. It covered volunteer COMAH operators from several industrial sectors, and despite being a self-selecting group already engaged with OT cyber security, none had fully achieved all the objectives expected for good cyber hygiene. HSE concluded that compliance across the wider sector was likely to be lower still.
Operators that made progress did so by engaging with the guidance and inspection process and working through what the requirements meant in practice. Awareness was not enough on its own; improvement came from applying structure, examining the arrangements behind the outcomes and acting on the findings.
The underlying problem is often not a conscious acceptance of risk. More commonly, responsibility sits somewhere between IT, engineering, operations and process safety without being fully owned by any of them.
“We have never had an incident” is not evidence that controls are effective. It may simply mean the organisation has not detected one.
Triton demonstrated what that absence of visibility can mean. The malware targeted a safety instrumented system at a petrochemical facility and was discovered only after an error in its own code caused the controllers to enter a protective state.
Triton remains important because it crossed directly into process safety. A safety instrumented system is process safety equipment, and malware capable of interfering with it creates a process safety threat that has arrived through the network.
From outcomes to evidence-based assurance
A credible self-assessment should connect four things:
- · the outcome the organisation needs to achieve;
- · the management and technical functions supporting it;
- · the relationships and dependencies between those functions; and
- · the evidence showing that the arrangements work in practice.
Assurance comes from examining the evidence collectively and testing whether the different parts of the system support one another. Done properly, self-assessment allows an organisation to look beneath the outcome, identify where functions are disconnected and demonstrate improvement over successive assessment cycles.
The CAF provides the outcomes. A structured, evidence-based methodology connects them to the management functions, technical controls, and process safety dependencies that determine whether they can be genuinely achieved.
That is what turns self-assessment from a compliance exercise into organisational understanding—and it is the discipline around which OpenPSM is built. For further information visit - https://openpsm.uk/